10,600 nm, 2,940 nm, 1,927 nm: Resurfacing Wavelength for Your Clinic

When buying clinic equipment people compare brands, wattage, screens and price. The wavelength is a property that is fixed at the time of the signal creation. There are three major bands of ablative resurfacing – 10,600, 2,940 and 1,927 nm. It’s not the ranking, it’s three different instruments. Each removes different amount of the tissue to different depth. You don’t want to purchase an inferior machine, you want to purchase a machine you cannot not do the cases you sell!

There is one law for them all!

All three are directed towards the water. The difference is the rate at which water absorbs the light, and this determines the depth the light travels till it is absorbed.

10,600 nm – the absorption is about 800 cm⁻¹. Light has a 15-30 µm diameter, removes 20-60 µm during each pass, and coagulates 60-150 µm. At 2,940 nm the absorption coefficient runs at 12,000 cm⁻¹ – fifteen times higher. Within just a few micrometres, the beam is depleted, and removes 2-5 µm per J/cm², with 10-50 µm of residual heat left behind. They are bounded by the thulium band at 1927 nm which is 100-300 µm deep.

The depth is determined by the wavelength and not the power dial. The higher the wattage of the 1,927 nm system, the more heat you’ll get at 200 µm. It will not provide you with a CO2 procedure.

What exactly does each wavelength do?

10,600 nm CO2 – remodeling. The deepest heat and highest collagen contraction per session. The wavelength that is used to treat atrophic acne scars, surgical scars, burn scars, deeper rhytides and – in the surgical mode – seborrheic keratosis and skin tags. The trade-off is 5-10 days downtime and the maximum PIH risk in Fitzpatrick IV-VI. Parameters which are most important (and not the wattage) are the pulse width (0.1 – 10 ms) and dot spacing (0.1 – 2.6 mm) of the 60 W RF platform. They decide the amount of unaltered tissue between the columns.

2,940 nm Er:YAG – precision. The procedure is precise and the thermal spread is small due to absorption in the order of few micrometres. The down time is 3-7 days, what makes this wavelength the best for the sensitive areas, superficial actinic damage and what makes it best for patients who don’t want to take a week off. The problem is the shrinkage. Small residual heat leaves behind lesser tightening after each session and lesser number of passes are required for CO2 than 2-4 passes required for small residual heat. The vessels will bleed in pinpoints – Er:YAG will not seal the vessels like CO2.

1,927 nm thulium – tone. Superficial – and that’s where the melanin is at – 100–300 µm. Pigment and texture tool – dyschromia, lentigines, photoaging, pores, with the downtime one to three days. Frequently adopted as a scar instrument and that’s not a scar instrument. The remodeling is limited by depth and complaints begin to emerge after the third month.

1,550 nm Er:Glass – adjunct. Non-ablative and deep, stratum corneum is not broken, minimal downtime, mild improvement, recurring revenue. Structural scars are not to be replaced by the ablative platform.

CO2 10,600 Er:YAG 2,940 Thulium 1,927 Er:Glass 1,550
Ablation per pass 20–60 µm 2–5 µm per J/cm² Non-ablative Non-ablative
Thermal zone 60–150 µm 10–50 µm Superficial Dermal
Optical depth 15–30 µm 1–5 µm 100–300 µm 400–1,500 µm
Downtime 5–10 days 3–7 days 1–3 days 0–2 days
Strongest use Scars, deep rhytides Superficial resurfacing Pigment, tone, pores Maintenance
PIH risk, type IV–VI Highest Moderate Lower Low
Sessions, typical 1–3 2–4 2–3 3–6

Three clinics are available to cover the majority of buyers. CO2 will be the primary treatment in scar focused clinic, with 1,550 nm for patients who choose to forgo ablative downtime. In case you are running tone and pigmentation business, 1,927 nm will be the right choice for you; apply CO2 indiscriminately and expect equal number of results and pigmentary complications. And in case your business model is volume and minimal downtime, build your business on the non-ablative bands, bringing in CO2 for selective cases.

Multi-wavelength cabinets appear to be a quick-cut solution. But, in reality, it is a compromise – a single console with shared optics, cooling and the tube was not always the match to the dedicated system. If you have one cabinet, then select the wavelength for your top 3 procedures.

Here are three questions to consider before signing:

Which 3 procedures will profit this machine? If they’re not listed, then chances are you don’t require 10,600 nm.

How much downtime does my market have to endure? Some markets give 5-10 days, some do not.

Do the scanner controls control density? Spot size: 0.1-20 mm, spacing: 0.1 mm, and pulse width is independent. Results repeatability is due to density.

Then the not so exciting part. Written hours rating of the tube and the type of the tube. Delay in spare parts delivery. Provide evidence in support of the medical statement given in your country. the CE mark is often associated only with the electrical safety – before applying the machine to the patient, ask which regulation the certificate is for.